3x Axial fans 4-wire 12V
3x Axial fans 4-wire 12V
1x I/O Module Moxa ioLogik E1212 (8x digital inputs, 8x digital inputs/outputs)
1x I/O Module Moxa ioLogik E1240 (8x analog inputs)

Revision as of 12:49, 13 April 2022

Main Page -> Hardware Documentation and Howto's

Getting Started

Documentation

pRU

pRU Registers and Bus System

The pRU bus system is connecting the various modules on the FPGA to a common master, the Microblaze Subsystem. Each of the modules is associated with a given BASE-ADDRESS specified in the pRU Control Interface Document. Note that several instances do exist for certain modules. E.g. there are one alpide_data instance for each ALPIDE chip connected to the pRU. To communicate with a specific instance one needs to add an offset of 0x1000 times the instance number to the module base address.

E.g. if you want to communicate with the

  • 1st instance: <ALPIDE_DATA_BASEADDR>
  • 2nd instance: <ALPIDE_DATA_BASEADDR> + (0x1000 * (2-1))
  • 16th instance: <ALPIDE_DATA_BASEADDR> + (0x1000 * (16-1))
Module Registers

PTB-specific Module Registers

Transition Card (TC)

ALPIDE Chip

ALPIDE Bonding and Mounting

Chip Cable

9 Chip String

  • 2019 November 5
  • Some of the aluminium traces on the flex cable broke by the tail of the cable (near the ZIF stiffener). Current design and possible modifications shows the current design and two possible modifications. It has been decided that new designs will use the design 1 modification and longer ZIF-stiffener (30 mm long).

Production Test Box (PTB)

FPGA Mezzanine Card (FMC)

mTower

Cooling Laboratory Setup

1x LAUDA Ultracool UC 4 is used for water cooling in the laboratory now (data sheet and manual).

1x Digital flow switch with temperature sensor for the cold plate (flow rate 13,6 l/min) SMC PF3W520S-04-2T-R-X128

1x Digital flow switch with temperature sensor for the tracking layers (flow rate 3,2 l/min) SMC PF3W504S-03-2T-R-X128

2x Digital flow monitor (SMC PFG310-SV)

4x Meas Heavy Industrial Pressure Transmitter (M5131-70010X-004BC)

3x Axial fans 4-wire 12V

1x I/O Module Moxa ioLogik E1212 (8x digital inputs, 8x digital inputs/outputs)